...

Specialized in Electrical Connectivity Solutions

Search
Close this search box.
HomeinsightsWire harness TechnologyHow to Choose an Industrial Wire Harness for OEM Equipment

How to Choose an Industrial Wire Harness for OEM Equipment

Industrial wire harness for OEM equipment with wires and connectors

Choosing an industrial wire harness for OEM equipment requires more than selecting wires and connectors that meet basic electrical requirements. The harness must fit the equipment layout, connect components correctly, withstand its operating environment, and remain practical to install and maintain.

For OEM engineers and purchasing teams, the best approach is to define the equipment requirements first and then translate them into a clear harness specification. This guide explains the main factors to consider, from electrical and mechanical requirements to customization, testing, and supplier evaluation.

1. Start With the OEM Equipment Requirements

Before requesting a quotation, determine how the wire harness will be used inside the equipment. The application defines the electrical, mechanical, and environmental requirements that the harness must satisfy.

Define the Electrical Requirements

Start with the electrical characteristics of the circuits. Important information includes:

  • Operating voltage
  • Current requirements
  • Number of circuits
  • Power and signal circuits
  • AC or DC operation
  • Sensor or control signals
  • Communication requirements

Power circuits may require different wire specifications from low-current control or signal circuits. Defining these requirements early helps prevent problems caused by undersized conductors, unsuitable insulation, or incompatible terminals.

Define the Physical Requirements

The harness also needs to fit the equipment mechanically. Consider the available installation space, total harness length, branch locations, connector orientation, and routing path.

If the harness passes through a narrow space or around moving components, bend radius and flexibility become especially important. For OEM equipment, these details should ideally be defined using wiring diagrams, assembly drawings, or CAD data.

2. Select the Right Wire and Connector Configuration

Once the equipment requirements are clear, select the wire and connector configuration that matches the application.

Choose the Appropriate Wire Construction

Wire selection should consider more than conductor size. Depending on the equipment, the harness may require specific conductor materials, insulation types, flexibility, or temperature resistance.

Current capacity is an important starting point, but wire selection may also be affected by:

  • Operating temperature
  • Harness length
  • Installation method
  • Required flexibility
  • Mechanical movement
  • Environmental exposure

For equipment with repeated movement, a flexible wire construction may be more appropriate than a standard fixed-installation wire.

Match Connectors and Terminals to the Equipment

Connectors and terminals must match the mating components and the available installation space. Check the connector type, number of positions, terminal compatibility, locking mechanism, and required protection.

The connector should also suit how the equipment will be assembled and serviced. For example, frequently disconnected components may benefit from connectors designed for repeated mating, while equipment exposed to dust or moisture may require additional sealing.

For an OEM project, connector part numbers or approved specifications should be included in the harness documentation whenever possible. This reduces ambiguity during prototype and mass production.

3. Consider Mechanical and Environmental Conditions

An industrial wire harness can be exposed to conditions that are not present in typical indoor electronics. These conditions should be considered before finalizing the design.

Movement, Vibration, and Bending

Determine whether the harness will remain stationary or move during equipment operation.

Robotic systems, automated machinery, actuators, and other moving equipment may expose wires to repeated bending, vibration, or mechanical stress. In these applications, the harness design may need appropriate flexible cables, strain relief, protective sleeving, and routing methods.

The branch position is also important. A poorly positioned branch can increase bending stress or make installation more difficult.

Temperature, Moisture, Dust, and Chemicals

The working environment can affect both the wire insulation and connectors. Consider whether the equipment will operate in:

  • High or low temperatures
  • Humid environments
  • Areas exposed to water or oil
  • Dusty industrial locations
  • Environments containing chemicals
  • Outdoor installations

The selected wire and connector materials should be compatible with these conditions. Where necessary, sealing, protective sleeving, or other forms of environmental protection can be incorporated into the harness design.

4. Decide the Level of Customization

OEM equipment often has its own wiring architecture, so a standard cable may not provide the required combination of length, connectors, branches, and terminal configurations.

An industrial wire harness can be customized in several ways, including:

  • Harness length
  • Branch locations
  • Wire and cable types
  • Connector combinations
  • Terminal types
  • Pin-to-pin wiring
  • Labels and identification
  • Protective sleeving
  • Shielding
  • Strain relief

Customization should be based on the actual equipment design rather than adding unnecessary features. A well-defined harness can simplify assembly because technicians can install the wiring according to the equipment layout instead of modifying individual wires during production.

5. Check Testing and Quality Requirements

A harness that looks correct is not necessarily electrically correct. OEM buyers should confirm how the finished assembly will be inspected and tested.

Common checks include:

  • Continuity testing
  • Pin-to-pin verification
  • Insulation testing
  • Terminal and connector inspection
  • Visual inspection
  • Dimensional inspection
  • Functional testing when required

Continuity and pin-to-pin testing are particularly useful for identifying incorrect connections in multi-branch harnesses. Dimensional and visual checks can also confirm that the finished assembly corresponds to the approved drawing.

For production programs, it is useful to establish inspection requirements before mass production begins. This gives the OEM and supplier a common quality standard rather than relying on visual acceptance alone.

6. Evaluate the Wire Harness Supplier

Industrial wire harness for OEM equipment with wires and connectors

Selecting an industrial wire harness is also a matter of evaluating whether the supplier can support the complete OEM requirement.

Consider the supplier’s ability to provide:

Engineering support: Can the supplier review drawings, wiring diagrams, connector specifications, and installation requirements?

Customization: Can the supplier produce different lengths, branches, terminals, and connector configurations?

Prototyping: Can the supplier provide samples for fit, assembly, and electrical verification before production?

Testing: Does the supplier have appropriate inspection and electrical testing procedures?

Production capability: Can the supplier maintain consistent assembly quality when the project moves from prototype to repeat production?

Documentation: Can the supplier maintain drawings, wiring information, part specifications, and production records?

For OEM projects, these capabilities can be just as important as the initial unit price. A supplier that understands the engineering requirements can help reduce communication problems when the harness moves from prototype to production.

7. Prepare a Clear RFQ for an Industrial Wire Harness

A detailed RFQ helps the supplier understand the project and provide a more accurate quotation. Instead of sending only a required quantity and a general description, provide as much technical information as is available.

InformationWhat to Provide
ElectricalVoltage, current, number of circuits
WiringWire type, gauge, and pin-to-pin connections
ConnectorsPart numbers or connector specifications
DimensionsOverall length, branches, and routing requirements
EnvironmentTemperature, moisture, vibration, chemicals
DrawingsWiring diagram, assembly drawing, or CAD data
QuantityPrototype quantity and estimated production volume
TestingRequired inspection and test methods

If some specifications have not yet been finalized, identify them clearly instead of leaving them ambiguous. The supplier can then confirm feasibility and recommend suitable options before production.

A complete RFQ also makes it easier to compare quotations because different suppliers are responding to the same technical requirements.

8. BRIFAR Industrial Wire Harness Solutions

BRIFAR provides industrial wire harness solutions for OEM equipment requiring customized power and signal connections. Its Industrial Wire Harness offering can be configured according to equipment wiring requirements, including wire, terminal, connector, length, and harness structure.

For OEM projects, the harness can be developed around application-specific drawings and connection requirements rather than relying on a one-size-fits-all configuration. This approach is suitable for equipment manufacturers that need consistent assemblies for prototype development and production.

When discussing a custom industrial wire harness, providing the wiring diagram, connector information, dimensions, operating environment, and expected quantity can help BRIFAR evaluate the project more efficiently.

FAQ

What is an industrial wire harness used for?

An industrial wire harness organizes and connects multiple wires, terminals, and connectors within industrial equipment. It can carry power, control, sensor, or communication signals between different components.

How do I choose the right wire gauge for an industrial wire harness?

Start with the required current and voltage, then consider wire length, operating temperature, installation conditions, flexibility, and other application requirements. The final wire specification should be verified against the equipment design.

Can an industrial wire harness be customized for OEM equipment?

Yes. OEM wire harnesses can be customized by length, connector type, terminal configuration, branch location, pin-to-pin wiring, labeling, shielding, and protective components according to the equipment requirements.

What information should I provide when ordering a custom wire harness?

Useful information includes the wiring diagram, wire specifications, connector or terminal details, harness dimensions, branch locations, operating environment, required quantity, and testing requirements.

How can I verify the quality of an industrial wire harness?

Review the supplier’s inspection and testing process. Depending on the application, this may include continuity, pin-to-pin, insulation, connector, dimensional, visual, and functional checks.

Table of Contents

Related Products

Professional Electrical Connection Manufacturer

Scroll to Top

Request a Quote

Tell us what you need. Add a quantity, requested delivery date or drawing for a more specific quotation.